Sign In | Join Free | My burrillandco.com
Home > Battery Grading System >

Universities Power Battery Grading System 1 Channel For EV

    Buy cheap Universities Power Battery Grading System 1 Channel For EV from wholesalers
     
    Buy cheap Universities Power Battery Grading System 1 Channel For EV from wholesalers
    • Buy cheap Universities Power Battery Grading System 1 Channel For EV from wholesalers
    • Buy cheap Universities Power Battery Grading System 1 Channel For EV from wholesalers
    • Buy cheap Universities Power Battery Grading System 1 Channel For EV from wholesalers

    Universities Power Battery Grading System 1 Channel For EV

    Ask Lasest Price
    Brand Name : Neware
    Model Number : CT-4001-5V1000A-NA
    Certification : CE
    Price : USD negotiation per Unit
    Payment Terms : T/T
    Supply Ability : 10 Units Per Month
    Delivery Time : 45 word days
    • Product Details
    • Company Profile

    Universities Power Battery Grading System 1 Channel For EV

    Neware Power Battery Formation and Grading System EV Battery Cycle Life Tester


    Based on Neware fifth - generation testing system . Mainly used in Power battery condition simulation , Pulse charging and discharging , Cycle Life , Rate of charge and discharge .


    Using dynamic power or current waveform to simulate electric vehicle driving road . Simulate the electric vehicle driving road conditions through the dynamic power or current waveform .


    CT-4000 mainly applies for institutions , colleges and universities and EV battery manufacturers .


    Driving Cycle Simulation

    Driving cycles are used to simulate car fuel economy at different operating conditions . There are many driving schedules or driving cycles that are issued by various agencies or institutes. To simulate EV , you need to convert the speed output into the power consumption or regeneration of the energy storage device installed on the vehicle .


    Accurate Timing

    Capacity or energy is calculated on time basis with the voltage and current measured , thus the timing accuracy will greatly affect the capacity calculated . To a general constant current or other constant testing regimes, this effect may not that easy to be observed .


    Recycle Battery Function

    If you have recovery battery pack , like Toyota Prius battery pack , generally, each piece has 6 single Ni - MH cell , then several pieces batteries assembed in one pack , and you need to check each single cell for capacity , cyclie life , resistance , etc . Then assemble the battery cell after sorting by capacity , resistance . You will get the new battery pack . And last you will test the battery pack to check the real capacity and other function parameter .


    Simulation - the Way You Look into Reality

    You know battery capacity at at constant current , or power , or load . But the reality is that no the energy is drawn by a constant variable . Your capacity or energy tested under constant conditions can only be a general one , and the cycle life tested such regime can also be largely deviated from reality . To have a better master of reality, simulation is introduced . GSM pulse is of such kind for phone batteries . for EV batteries , Drive Cycle Simulation is used .


    Project index

    Parameter index

    resolutionAD 16bit , DA 16bit
    Input ResistanceMore than 1MΩ
    Input Power8861W
    Channel FeaturesConstant Current Source and Constant Voltage Source with Independent pairs of Closed - loop Structure
    Channel Control ModeIndependent Control
    VoltagePer Channel Voltage Range25mV - 5V
    Discharge Min Voltage2.5V
    Accuracy0.05 percent of FS
    Stability0.05 percent of FS
    TimeCurrent Response Time20ms
    ChargeCharge ModeCCCharge , CVCharge , CCCVCharge , CPCharge
    End ConditonVoltage , Current , Relative Time , Capacity , -deltaV
    DischargeDischarge ModeCCD , CPD , CRD
    End ConditionVoltage , Current , Relative Time , Capacity
    PulsechargeCCC , CPC
    DischargeCCD , CPD
    Min Pulse Width500ms
    Automated SwitchAutomated swith from charge to discharge for each pulse
    End ConditionVoltage, Test Time
    CycleLoop Measure Range65535 times
    Max Steps Per Loop254
    Nested LoopNested loop Function , Max Support 3 Layers
    ProtectionSoftware ProtectionPower - down Data Protection
    Off - line Testing Function
    Setting Protection Condition,Setting Parameter - Low Voltage limit , Upper Voltage limit , Low Current limit , Upper Current limit , Delay Time
    IP protection levelProtection level IP20
    A Means of Communication of Upper MachineTCP / IP Protocol
    Data OutputEXCEL , TXT , Graph
    Communication InterfaceEthernet Port
    Per Unit Main Channels No.1

    Universities Power Battery Grading System 1 Channel For EV

    Quality Universities Power Battery Grading System 1 Channel For EV for sale
    Inquiry Cart 0
    Send your message to this supplier
     
    *From:
    *To: Neware Technology Limited
    *Subject:
    *Message:
    Characters Remaining: (0/3000)