    Brand Name : Neware
    Model Number : CE-4008-50V20A-NA
    Certification : CE
    Price : USD Negotiation per Unit
    Payment Terms : T/T
    Supply Ability : 50 Units Per Month
    Delivery Time : 45 working days
    • Product Details
    • Company Profile

    Electronic Reading Neware Battery Test System 8 Channel CE Certified

    Neware Battery Testing Device Electronic Reading Machine Battery Capacity Cycler


    Neware battery testers provide good accuracies both for voltage and current . This ensures you get the most reliable data from your tests .


    A measurement system can be accurate but not precise , precise but not accurate , neither , or both .


    Software Feature

    1 , Provide timely instructions , warnings, and intelligent support .

    2 , Compliance CE Certified .

    3 , Windows-based software interface for easy operation .

    4 , Uses standard SQL data - base management .

    5 , The user can define the curve by different types such as voltage - time curve , current - time curve , capacity - voltage curve , loop times - charge / discharge capacity curve , loop times - charge / discharge efficiency curve , etc . to make curves be compared both by visually and statistically .

    6 , Real - time monitoring windows and integrated graph / data windows can set various working modes for measuring capacity and cycle life of all types of rechargeable batteries , such as:constant current discharge , constant current charge , constant voltage charge , rest , as well as voltage , current , time , capability , negative voltage slope , and other limit conditions .

    7 , Neware battery testers provide good prrecision meanwhile .

    8 , To get an overall performance of a measurement system , Measurement system analysis MSA is usually introduced for the study .


    DCIR - Direct Current Internal Resistance

    1 . Direct current internal resistance of batteries is the r esistance of current flowing through the battery , with the standard unit of measurement called the ohm .

    2 . The value of DCIR is not fixed , and varies depending on multiple factors , such as battery materials , electrolyte concentration , temperature , and depth of discharge .

    3 . The variation of DCIR has a great influence on battery discharge performance , especially for high power batteries . In general , the better the battery , the lower the internal resistance .

    4 . Therefore , most battery manufacturers identify DCIR as a key indicator to evaluate battery quality .

    5 . The method of DCIR measurement is to inject high current into the anodeand cathode of the battery in a short period , and then record the changes of battery voltage and charge / discharge current . To calculate DCIR by Ohm Law , voltage variation is divided by current variation .


    Project index

    Parameter index

    resolutionAD 16bit , DA 16bit
    Input ResistanceMore than 1MΩ
    Input Power10532W
    VoltagePer Channel Voltage Range250mV - 50V
    Discharge Min Voltage3V
    Accuracy0.05 percent of FS
    Stability0.05 percent of FS
    TimeCurrent Response Time20ms
    ChargeCharge ModeCCCharge , CVCharge , CCCVCharge , CPCharge
    End ConditonVoltage , Current , Relative Time , Capacity , -deltaV
    DischargeDischarge ModeCCD , CPD , CRD
    End ConditionVoltage , Current , Relative Time , Capacity
    PulsechargeCCC , CPC
    DischargeCCD , CPD
    Min Pulse Width500ms
    Automated SwitchAutomated swith from charge to discharge for each pulse
    End ConditionVoltage, Test Time
    CycleLoop Measure Range65535 times
    Max Steps Per Loop254
    Nested LoopNested loop Function , Max Support 3 Layers
    ProtectionSoftware ProtectionPower - down Data Protection
    Off - line Testing Function
    Setting Protection Condition,Setting Parameter - Low Voltage limit , Upper Voltage limit , Low Current limit , Upper Current limit , Delay Time
    IP protection levelProtection level IP20
    Voltage and Current Testing Sample4 - wire connecting
    NoiseLess than 85dB
    DatabaseMySQL Database
    A Means of Communication of Upper MachineTCP / IP Protocol
    Communication InterfaceEthernet Port
    Per Unit Main Channels No.8

    Electronic Reading Neware Battery Test System 8 Channel CE Certified

    Quality Electronic Reading Neware Battery Test System 8 Channel CE Certified for sale
    Inquiry Cart 0
    Send your message to this supplier
     
    *From:
    *To: Neware Technology Limited
    *Subject:
    *Message:
    Characters Remaining: (0/3000)